- Title
- A simple approach to using an amorphous silicon EPID to verify IMRT planar dose maps
- Creator
- Lee, Christopher; Menk, Fred; Cadman, Patrick; Greer, Peter B.
- Relation
- Medical Physics Vol. 36, Issue 3, p. 984-992
- Publisher Link
- http://dx.doi.org/10.1118/1.3075817
- Publisher
- American Association of Physicists in Medicine (AAPM)
- Resource Type
- journal article
- Date
- 2009
- Description
- A simplified method of verifying intensity modulated radiation therapy (IMRT) fields using a Varian aS500 amorphous silicon electronic portal imaging device (EPID) is demonstrated. Unlike previous approaches, it does not involve time consuming or complicated analytical processing of the data. The central axis pixel response of the EPID, as well as the profile characteristics obtained from images acquired with a 6 MV photon beam, was examined as a function of field size. Ion chamber measurements at various depths in a water phantom were then collected and it was found that at a specific depth dref, the dose response and profile characteristics closely matched the results of the EPID analysis. The only manipulation required to be performed on the EPID images was the multiplication of a matrix of off axis ratio values to remove the effect of the flood field calibration. Similarly, dref was found for 18 MV. Planar dose maps at dref in a water phantom for a bar pattern, a strip pattern, and 14 clinical IMRT fields from two patient cases each being from a separate anatomical region, i.e., head and neck as well as the pelvis, for both energies were generated by the Pinnacle planning system (V7.4). EPID images of these fields were acquired and converted to planar dose maps and compared directly with the Pinnacle planar dose maps. Radiographic film dosimetry and a MapCHECK dosimetry device (Sun Nuclear Corporation, Melbourne, FL) were used as an independent verification of the dose distribution. Gamma analysis of the EPID, film, and Pinnacle planar dose maps generated for the clinical IMRT fields showed that approximately 97% of all points passed using a 3% dose/3mm DTA tolerance test. Based on the range of fields studied, the author's results appear to justify using this approach as a method to verify dose distributions calculated on a treatment planning system, including complex intensity modulated fields.
- Subject
- amorphous silicon; EPID dosimetry; intensity modulated; TPS verification
- Identifier
- uon:7062
- Identifier
- http://hdl.handle.net/1959.13/925009
- Identifier
- ISSN:0094-2405
- Reviewed
- Hits: 3787
- Visitors: 2651
- Downloads: 0
Thumbnail | File | Description | Size | Format |
---|