- Title
- Comparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents
- Creator
- Scott, Joseph J.; Rowlands, Alex V.; Cliff, Dylan P.; Morgan, Philip J.; Plotnikoff, Ronald C.; Lubans, David R.
- Relation
- Funding BodyARCGrant NumberDE140101588 http://purl.org/au-research/grants/arc/DE140101588
- Relation
- Journal of Science and Medicine in Sport Vol. 20, Issue 12, p. 1101-1106
- Publisher Link
- http://dx.doi.org/10.1016/j.jsams.2017.04.017
- Publisher
- Elsevier
- Resource Type
- journal article
- Date
- 2017
- Description
- Objective: To determine the comparability and feasibility of wrist- and hip-worn accelerometers among free-living adolescents. Design: 89 adolescents (age = 13-14 years old) from eight secondary schools in New South Wales (NSW), Australia wore wrist-worn GENEActiv and hip-worn ActiGraph (GT3X+) accelerometers simultaneously for seven days and completed an accelerometry behavior questionnaire. Methods: Bivariate correlations between the wrist- and hip-worn out-put were used to determine concurrent validity. Paired samples t-test were used to compare minutes per day in moderate-to-vigorous physical activity (MVPA). Group means and paired sample t-tests were used to analyze participants' perceptions of the wrist- and hip-worn monitoring protocols to assist with determining the feasibility. Results: Wrist-worn accelerometry compared favorably with the hip-worn in average activity (r = 0.88, p < 0.001) and MVPA (r = 0.84 p < 0.001, mean difference = 3.54 min/day, SD = 12.37). The wrist-worn accelerometer had 50% fewer non-valid days (75 days, 12%) than the hip-worn accelerometer (n = 152, 24.4%). Participants reported they liked to wear the device on the wrist (p < 0.01), and that it was less uncomfortable (p = 0.02) and less embarrassing to wear on the wrist (p < 0.01). Furthermore, that they would be more willing to wear the device again on the wrist over the hip (p < 0.01). Conclusions: Our findings reveal there is a strong linear relationship between wrist- and hip-worn accelerometer out-put among adolescents in free-living conditions. Adolescent compliance was significantly higher with wrist placement, with participants reporting that it was more comfortable and less embarrassing to wear on the wrist.
- Subject
- ActiGraph; GENEActiv; physical activity; compliance; perceptions; youth
- Identifier
- http://hdl.handle.net/1959.13/1388465
- Identifier
- uon:32763
- Identifier
- ISSN:1440-2440
- Language
- eng
- Reviewed
- Hits: 16979
- Visitors: 4662
- Downloads: 1
Thumbnail | File | Description | Size | Format |
---|