Please use this identifier to cite or link to this item: http://hdl.handle.net/1959.13/916225
- Title
- Fault detection on multicell converter based on output voltage frequency analysis
- Author/Creator
-
Lezana, Pablo;
Aguilera, Ricardo;
Rodríguez, José
- Institution
- The University of Newcastle. Faculty of Engineering & Built Environment, School of Electrical Engineering and Computer Science
- Description
- Multilevel converters use a large amount of semiconductors, allowing the reconfigurate of the converter to work even on internal fault condition. This paper presents a method to detect faulty cells in a cascaded multicell converter requiring just one voltage measurement per output phase. The method is based on high-frequency harmonic analysis, using a dynamic prediction of their behavior, avoiding erroneous detection on transients while keeping the precision under real fault events. Once the faulty cell is detected, it can be bypassed allowing the converter to keep working according to previously reported techniques. Experimental results confirm accurate and fast fault detection, with a good rejection to normal operation transients.
- Relation
- IEEE Transactions on Industrial Electronics Vol. 56, Issue 6, p. 2275-2283
- Publisher Link
- http://dx.doi.org/10.1109/TIE.2009.2013845
- Date
- 2009
- Publisher
- Institute of Electrical and Electronics Engineers (IEEE)
- Keyword(s)
-
digital control;
fault diagnosis;
multilevel systems;
power electronics
- Resource Type
- journal article
- Identifier
- http://hdl.handle.net/1959.13/916225
- Identifier
- ISSN:0278-0046
- Reviewed

40 Visitors
42 Hits