- Title
- Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry
- Author/Creator
-
Vial, Philip;
Greer, Peter B.;
Oliver, Lyn;
Baldock, Clive
- Institution
- The University of Newcastle. Faculty of Science & Information Technology, School of Mathematical and Physical Sciences
- Description
- Electronic portal imaging devices (EPIDs) integrated with medical linear accelerators utilize an indirect-detection EPID configuration (ID-EPID). Amorphous silicon ID-EPIDs provide high quality low dose images for verification of radiotherapy treatments but they have limitations as dosimeters. The standard ID-EPID configuration includes a high atomic number phosphor scintillator screen, a 1 mm copper layer, and other nonwater equivalent materials covering the detector. This configuration leads to marked differences in the response of an ID-EPID compared to standard radiotherapy dosimeters such as ion chambers in water. In this study the phosphor and copper were removed from a standard commercial EPID to modify the configuration to a direct-detection EPID (DD-EPID). Using solid water as the buildup and backscatter for the detector, dosimetric measurements were performed on the DD-EPID and compared to standard dose-in-water data for 6 and 18 MV photons. The sensitivity of the DD-EPID was approximately eight times less than the ID-EPID but the signal was sufficient to produce accurate and reproducible beam profile measurements for open beams and an intensity-modulated beam. Due to the lower signal levels it was found necessary to ensure that the dark field correction (no radiation) DD-EPID signal was stable or updated frequently. The linearity of dose response was comparable to the ID-EPID but with a greater under-response at low doses. DD-EPID measurements of field size output factors and beam profiles at the depth of maximum dose (dmax), and tissue-maximum ratios between the depths of 0.5 and 10 cm, were in close agreement with dose in water measurements. At depths beyond dmax the DD-EPID showed a greater change in response to field size than ionisation chamber measurements and the beam penumbrae were broader compared to diode scans. The modified DD-EPID configuration studied here has the potential to improve the performance of EPIDs for dose verification of radiotherapy treatments.
- Relation
- Medical Physics Vol. 35, Issue 10, p. 4362-4374
- Publisher Link
- http://dx.doi.org/10.1118/1.2975156
- Date
- 2008
- Publisher
- American Association of Physicists in Medicine (AAPM)
- Keyword(s)
-
dosimeters;
dosimetry;
radiation therapy
- Resource Type
- journal article
- Identifier
- http://hdl.handle.net/1959.13/43263